The difference between a $300 pipe repair and a $3,000 drywall-and-remediation job is often just whether the leak was found before or after excessive wall opening. Our detection service in University Park uses the same methods utilities and insurance adjusters rely on โ to pinpoint the failure before anything is cut.

A pressure test tells us a leak exists. Detection equipment tells us precisely where.
Most effective on metal pipe under slab or in concrete โ materials that conduct sound efficiently. We establish a clean acoustic baseline by briefly shutting off the house before scanning.
Particularly effective inside insulated wall cavities and for finding the extent of moisture spread beyond the immediate leak point โ telling us not just where the pipe is failing but how far the moisture has already traveled.
Pressure decay testing is the standard by which we confirm a leak is present before committing detection equipment time. A rapid drop vs. a slow one also indicates the approximate size of the escape point.
For leaks that don't produce sufficient acoustic signature โ very slow leaks, polyethylene pipe, or leaks deep under concrete โ we introduce a nitrogen/hydrogen tracer gas mixture into the isolated pipe and use a calibrated gas detector at the surface to find where the gas escapes. Sensitive to concentrations far below what produces an audible acoustic signal.
Our detection service covers the full property, not just the obvious locations.
Thermal imaging supplements acoustic detection for slab leaks, identifying the thermal anomaly that appears on the floor surface as water migrates through the concrete.

We document the thermal anomaly, mark the approximate pipe location, and recommend a minimal access cut rather than a wide wall opening โ typically saving hundreds in drywall repair costs.
We also perform leak correlation surveys for longer line runs, using two listening points to triangulate the failure location mathematically.
Irrigation system leaks in main supply and lateral runs are found by isolating zones with the irrigation controller and pressure-testing each zone individually. Zone-by-zone testing narrows the failure to the smallest possible section.

We format detection reports specifically for insurance submission and provide documentation on our detection equipment and methodology to claims adjusters on request.
Commercial buildings have complex pipe networks where a supply or drain leak can go undetected through multiple floors before surfacing. We approach commercial detection systematically โ zone-by-zone pressure isolation, thermal scan of suspect surfaces, and acoustic confirmation.
Finding a hidden leak isn't a single step โ it's a protocol that combines water loss confirmation, zone isolation, and targeted detection in sequence.
This step confirms we're looking for a real leak rather than a meter error or normal appliance cycling.
We isolate the supply system into zones โ hot side, cold side, individual branches โ and pressure-test each to determine which is losing water. This narrows the area of active search before detection equipment is deployed.
Within the isolated zone, we deploy thermal imaging first โ scanning walls, floors, and ceilings for moisture anomalies. Then acoustic equipment confirms the specific pipe location and narrows it to the tightest possible point. Tracer gas is added if acoustic results aren't conclusive.
Insurance-formatted reports are available for claims submission at the same standard โ no additional cost.

High-efficiency home with a slow leak โ about 1.5 gallons per hour. The tech used tracer gas after pressure testing confirmed the loss but acoustic detection couldn't localize it clearly. Gas detection found the escape at a micro-fitting under the slab in the utility corridor. Impressive work for a very difficult leak to find.
Ceiling stain in the living room kept coming back despite two drywall patches. Masters Plumbing Service ran the thermal camera and found the wet zone was traveling from a supply line joint 9 feet away, flowing down a horizontal framing member โ explaining why the patch kept failing. They marked the actual pipe location, we opened 8 inches of wall there, and the repair held. No more stain.
Commercial building with elevated water costs for six months. Masters Plumbing Service ran zone-by-zone pressure isolation across four floors, narrowed the loss to the third-floor kitchen supply branch, and located the failure with thermal imaging at a concealed valve body in the ceiling. No damage to the finished ceiling.
Masters Plumbing Service provides professional Leak Detection for residential and commercial properties throughout University Park and the surrounding University Park, IL service area. Detection appointments available most weekdays and Saturdays.

Call now to schedule โ most detection appointments available within 24โ48 hours.
๐ Call +1-844-833-0201 Now